Home / Heat Pump / Swimming Pool Heat Pump / Waterco ElectroHeat MKV Swimming Pool Heat Pump
Waterco's Electroheat MKV Pool Heat Pump
Greater interest in environmentally friendly and cost effective pool heating has seen an increase in the use of heat pumps around Australia to heat pools. To meet the demand, Waterco has added to its heat pump range the Electroheat MKV with heat output capacities 9, 12, 15, 19 and 23kW which are ideal for heating plunge pools, swim spas, spas and swimming pools as a solar replacement/season extender.
Overview of Waterco's Electroheat MKV Pool Heat Pump
The Electroheat MKV has been designed with ease of use and maintenance firmly in mind. For example, the LED control panel features a continuous digital pool temperature display and incorporates a self diagnosis system. In the event of a problem, the control panel will display diagnostic error codes.
It has been built with ozone friendly R410A refrigerant, described as the refrigerant of the future, which has dual benefits. Not only is it kinder to the environment, it also improves the heat pump’s performance.
Key features of the Electroheat MKV
- High density dual coil titanium heat exchanger
- Hydrophilic Blue Fin technology
- R410A refrigerant gas
- Temperature management and self diagnosis
- Compact dimensions of 126cm (W) x 36cm (L) x 71cm (H)
- Scroll compressor
- Weather proof cabinet
Energy Efficient Heating
A swimming pool is a major financial investment. Getting the most out of your pool, means keeping the pool at a swimmable temperature for the maximum number of hours in each day and the maximum number of days in each year. A pool heat pump will economically keep your pool warm 24 hours a day. Compared to gas and electric heaters, the Electroheat MKV pool heat pump range use just a fraction of the energy to generate the same amount of heat and unlike solar heating; there is no reliance on the sun as the latent heat in the air is used. For every 1kW of electricity consumed, Electroheat can produce up to 6kW of heat.
- Keep pool warm 24 hours a day.
- Unique modern robust design: noise & vibration reduction.
- Hydrophilic blue fin evaporator technology: improved corrosion resistance.
- Improved condensate collection: two fitted spigots to allow draiange hose connection.
- Refrigerant pressure gauge: confirmation of refrigerant gas charge.
- Smart Controls for temperature management and self diagnosis.
- Inbuilt Safety Devices for water flow, refrigerant level and compressor startup delay.
- Powerful Heat Transfer through the coiled heat exchanger maximising water contact.
- Dual Titanium Coil Heat Exchanger is highly resistant to ozone, iodine, baquacii, salt and chlorinated water.
- Scroll Compressor for improved efficiency and high performance.
- Weatherproof Cabinet for outdoor installation.
- R410A Refrigerant. Ozone friednly and maximises performance.
- Large Evaporator Area to extract more ambient heat.
Ideal For Heating
Swimming pools to extend the season.
Swimming pools for year round enjoyment.
Plunge pools.
Swim spas and spas
Warranty
10 years – Titanium heat exchanger
3 years – compressor
2 years – all other components
1 year – labour
Warranty – Commercial – 1 year
*Conditions apply.
Frequently Asked Questions
Should I use a pool cover?
The most effective way to prevent heat loss is to install a pool cover. An un-blankated pool loses 2-3 times more heat than a blanketed pool. Pool covers virtually eliminate evaporation and reduce heat loss by insulating the surface of the pool, greatly reducing pool heatings cost. As with all pool heaters, it would be advisable to use a pool cover at night, and when the pool is not in use.
What is the minimum ambient operating temperature?
The heat pump will actually operate down to an ambient air temperature of 10°C / 50°F, but with minimal heat output. Therefore, we recommend that the minimum operating temperature should be 10°C / 50°F.
What is the best location for the ElectroHeat?
The location of the ElectroHeat is very important in keeping installation costs to a minimum, while providing for maximum efficiency of operation as well as allowing adequate service and maintenance access.
The unit should be located as close as practically possible to the existing pool pump and filter to minimise water piping. The use of 90 degree bends and short radius elbows in the water piping should be kept to a minimum. The longer the distance from the pool, the higher the heat loss from the pricing.
Can the ElectroHeat be enclosed?
The ElectroHeat is designed for outdoor installations and should not be installed in totally enclosed areas such as a shed, garage, and et cetera, unless mechanical ventilation is provided to ensure adequate air exchange for proper operation. Re-circulation of cold discharged air back into the evaporator coil will greatly reduce unit’s heating capacity and efficiency.
What is the ElectroHeat's performance dependent on?
Performance will fluctuate depending on water and water temperatures. 5 important factors determine the performance of ElectroHeat:
- Size of the pool.
- The desired temperatures of the pool.
- Ambient air temperature – the waterm the air, the better the performance.
- The presence of a pool cover.
- The size of the heater.
What is the ElectroHeat's heater running time?
Most units should be sized to operate during the pool filtering cycle time of 8 – 12 hours daily, providing a steady flow of heated water. On warmer days the heater will run less because the heat loss will be less.
ElectroHeat heat pumps have a lower heating capacity on a BTU / hr basis compared to fossil fuel-based pool heaters such as gas heaters. Therefore, ElectroHeat heat pumps require longer operation to accomplish the desired temperature.
Between 10°C to 18°C, it will increase your water temperature by 3°C to 5.5°C a day. Over 21°C you should obtain an increase up to 0.8°C an hour and over 26°C up to 1.1°C an hour depending on the size of the pool, the size of the heat pump, the water temperature, and the ambient air temperature at the moment of operation.
Even though the ElectroHeat may require longer operation, it will still heat the pool far more economically.
How does ElectroHeat compare with solar heating and gas heating?
Solar
- Fuelled by the power of the sun, solar heating systems are a low-cost method of heating up your pool water.
- As solar heating is reliant on the sun, they are best used to extend the swimming season.
- Virtually no operating costs, just the cost of electricity to pump the pool water through the solar absorber on the roof.
Gas Heater
- Gas heaters are the fastest method for heating your pool, providing a comfortable temperature for swimming on demand. Gas is best for heating pools or spas for periods of time.
- Gas heaters can easily maintain any desired temperature regardless of the weather.
- Gas heaters are effective, but expensive to operate.
Heat pumps
- Heat pumps may not heat up the swimming pool as fast as gas heaters, but are more energy-efficient.
- Heat pumps require a small amount of electricity; its heat energy source is extracted from the ambient air.
Performance Specifications
| ElectroHeat MKV | |||||
|---|---|---|---|---|---|
| Specification | 9 kW | 12 kW | 15 kW | 19 kW | 23 kW |
| Nominal Power Output (kW)* | 9 | 12 | 15 | 19 | 23 |
| Nominal Heating Capacity BTU* | 30,700 | 41,000 | 51,000 | 64,000 | 78,500 |
| Product Code | 278095 | 278123 | 278152 | 278192 | 278232 |
| Power Output (kW): Air 26°C / Water 26°C / RH 63% | 8.9 | 11.7 | 13.5 | 18.5 | 21.8 |
| COP | 5.9 | 6.1 | 6.1 | 6.3 | 6.2 |
| Power Output (kW): Air 15°C / Water 24°C / RH 70% | 6.8 | 9.2 | 9.4 | 17.0 | 20.0 |
| COP | 4.8 | 4.8 | 4.3 | 5.8 | 5.7 |
| Supply Voltage (VAC) | 240 | 240 | 240 | 240 | 240 |
| Supply Voltage Phase | Single Phase | ||||
| Power Consumption (kW/h) | 1.5 | 1.9 | 2.2 | 2.9 | 3.5 |
| Full Load Amps | 9 | 12 | 12 | 22 | 30 |
| Minimum Breaker or Fuse (AMP) | 16 | 20 | 20 | 30 | 40 |
| Electrical Connection | 10A plug | 15A plug | Terminals | ||
| Min. / Max. Ambient Air Temperature (°C) | 10 / 40 | ||||
| Min. / Max. Water Inlet Temperature (°C) | 18 / 40 | ||||
| Water Connections (mm) | 40 mm | ||||
| Bypass External | 3 × 2 way | ||||
| Min. / Max. Water Flow Rate (LPM) | 120 – 230 | ||||
| Unit Dry Weight (kg) | 51 | 55 | 79 | — | |
| Dimensions W × L × H (mm) | 1269 × 361 × 717 | ||||
| Refrigerant | R410A | ||||
| Heat Exchanger Max. Pressure | 3.5 bar / 350 kPa | ||||
| Related products:Electroheat Pro range – Pool heat pumps for commercial applications.Electroheat ECO V range – Pool Heat pumps with inverter technology | |||||
Sizing Chart To Heat Your Pool To 28°C From September To April
| Pool Size (m) | Temperate Location* | Warm Location** | |||
|---|---|---|---|---|---|
| Up to 10 hrs / Day Run Time | Up to 10 hrs / Day Run Time | ||||
| Pool Size (m) | Litres | With Pool Cover | No Pool Cover | With Pool Cover | No Pool Cover |
| 3 × 6 | Up to 23,000 L | 9 kW | 15 kW | 9 kW | 9 kW |
| 3 × 7 | Up to 27,000 L | 9 kW | 15 kW | 9 kW | 9 kW |
| 4 × 7 | Up to 35,000 L | 12 kW | 23 kW | 9 kW | 15 kW |
| 4.5 × 8.5 | Up to 50,000 L | 15 kW | 31 kW | 9 kW | 19 kW |
| 5 × 10 | Up to 65,000 L | 19 kW | 23 kW × 2 | 12 kW | 23 kW |
| 5.5 × 11 | Up to 80,000 L | 23 kW | 23 kW × 2 | 15 kW | 15 kW × 2 |
| 6 × 12 | Up to 100,000 L | 15 kW × 2 | 23 kW × 3 | 19 kW | 19 kW × 2 |
Note: Size and performance are influenced by ambient temperature, humidity, use of a pool cover, night time temperature, pool location, wind factor, water features and if the unit is switched off over night. The recommended sizing in the table above is based on operating the unit up to 10 daytime hours with the pool subjected to normal suburban wind. No allowance has been made for the cooling effects of water features, negative edges or high wind areas. Therefore, any under sizing of the heater for your pool heating requirements is not the responsibility of Waterco. *Temperate Location (Sydney) :- Where minimum average daytime temperatures between September to April are not less than 18°C. ** Warm Location (Brisbane) :- Where minimum average daytime temperatures between September to April are not less than 24°C. *** Pool heating between May and August will require a larger heat pump. Consult www.watercocalculator.com or contact your local Waterco office. | |||||
Clearance
Included In The Box
Electroheat MKV Pool Heat Pump
Proof of Purchase
1 Year Commercial Warranty
Contact Us